Influence of the cross-sectional shape of the log elements to seal the log walls under the thermal loading
The aim of the research was to perform the medium-scale fire tests of two alternate samples of the log wall, using the radiant heat source. The radiant heat source consisted of a ceramic radiation panel with a maximum power of 50.5 kW.m-2 and a maximum temperature of 935°C. The samples varied by their geometric shape and the different design of the groove, which was sealed with glass mineral wool. A better result was achieved by a round wood sample with the circular section, which also resisted to high temperatures in the place of the groove and did not start burning with flame. The sample of the squared log elements started to burn with a flame. Temperature measured in the groove was much higher than in the first case.