Effects of fire retardants on mechanical properties and water resistance of Pinus massoniana particleboard

Pinus massoniana Lamb. wood particleboards processed by inorganic and organic fire retardants of two densities were prepared by isocyanate and MUF resin. Variations of internal bonding strength (IB), modulus of rupture (MOR), modulus of elasticity (MOE) and thickness swelling rate (TS) of particleboard were observed. Results demonstrated decreasing of IB from 0.81 MPa to 0.42 MPa and 0.36 MPa, MOR from 17.3 MPa to 12.5 MPa and 12.3 MPa, MOE from 1840 MPa to 1328 MPa and 1117 MPa, and increasing of TS from 5.2% to 15.1% and 11.2%, respectively, for the treated MUF particleboards of density 0.65 g.cm-3. Similarly, decreasing of IB from 0.93 MPa to 0.66 MPa and 0.64 MPa, MOR from 16.2 MPa to 10.6 MPa and 12.1 MPa, MOE from 1246 MPa to 1573 MPa and 1466 MPa, and increasing of TS from 6.7% to 7.1% and 6.0%, respectively, when isocyanate adhesive was used. The similar changes were showed when the density of particleboard was 0.75 g.cm-3. Improving density of particleboard appropriately and decrease density difference between the surface to chip layers could make the profile density curve tend to be stable, which could get a relatively high mechanical strength and water resistance. Synergistic effects between isocyanate and fire retardants was confirmed. The particleboard prepared with isocyanate was obviously superior to that prepared with MUF resin in all performances.

Investigation the fire hazard of plywoods using a cone calorimeter

A high-efficiency fire retardant composition was prepared with dicyandiamide, phosphoric acid, boric acid, borax, urea and magnesium sulfate and it was used to process veneers which were then to prepare the plywood. Meanwhile, heat release and smoke release from combustion of plywood were tested by a cone calorimeter, including heat release rate, mass loss rate, CO yield, CO2 yield and oxygen consumption. Results showed that the plywood with this fire retardant treatment had the better flame-retardant performance and smoke suppression effect as well as the stronger char-forming capability compared to plywood without fire retardant treatment. The average heat release rate, total heat release, average effective heat of combustion, total smoke release, CO yield and oxygen consumption of the plywood with fire retardant treatment were decreased by 63.72%, 91.94%, 53.70%, 76.81%, 84.99% and 91.86%, respectively. Moreover, the fire growth index of plywood treated by fire retardant was relatively low (3.454 kW·m-2·s-1) and it took longer time to reach the peak heat release rate, accompanied with slow fire spreading. The fire performance index was relatively high (0.136 s·m2·kW-1) and it took longer time to be ignited, thus leaving a long time for escaping at fire accidents. The fire hazard of plywood with fire retardant treatment was low, and its safety level was high.