Load-bearing capacity of metal connector plates depending on location and geometry of the nail

This paper presents results of the experimental determination of the load-bearing capacity of structural timber connections realized by nail metal connector plates as a function of nail location, length and diameter. Three different diameters of the nails have been used, specifically 2.0, 2.5, and 3.1 mm. The length of the metal nails in connectors has been determined after the detailed analysis, and kept at 20 mm during the experimental research. Nails distribution over the connector plate is such that it forms the series of equilateral triangles, so that a side of the triangle equals five times the diameter of the nails used. Preceding the testing, and while using the above listed parameters certain analysis has been done. In order to experimentally determine the load-bearing capacity of the nail metal connectors, the penetration depth, i.e. the length of the nails has been kept constant, while using three different nail diameters. The testing has been done on multiple samples in the accordance with Eurocode 5.