Evaluation of horizontal shear performance of larch CLT walls according to the edge connection shape
In this study, cyclic tests were performed on the larch CLT shear walls depending on the half lap reinforcement of half-lap connections and reinforced plywood of spline connections in order to evaluate the horizontal shear performance of the larch CLT walls. The test results show that there is no difference in residual strength depending on the reinforcement of half-lap connection, but their initial stiffness has been increased by 9%. There was no significant difference either in the residual strength of double spline connections depending on the application of reinforced plywood, while the spline reinforcement has failed to increase initial stiffness. All of the larch CLT walls constructed according to the edge connection shape were measured to have a strength reduction ratio of less than 10% in each horizontal displacement intervals and an equivalent viscous damping ratio of less than 10% for energy dissipation in the initial and final horizontal displacement intervals, thereby confirming that their excellent horizontal shear performance and seismic performance.